Maintenance
47
Troubleshooting
Operator maintenance or service is limited to battery
and fuse replacement. Any other required service must
be performed at an authorized Bird Service Center.
Refer to the following paragraphs for help in isolating
error conditions.
The Antenna Tester will not power up.
Power for the Antenna Tester can be provided in three
ways—the internal batteries, an AC mains adapter or an
optional automobile cigarette lighter adapter. Try to
power the tester using each available means. The inter
-
nal batteries may need charged, or if recently replaced,
are installed incorrectly. The AC mains adapter may not
be securely connected, may be damaged, or there is no
power supplied at the wall receptacle. The internal fuse
may have opened and requires replacement.
If the unit was recently opened, recheck P2, the bat-
tery connector, be sure it is securely connected. Follow
the instructions for battery and fuse replacement
when opening the unit.
NVRAM Test Fails
An NVRAM error indicates the information in nonvola-
tile RAM, a type of memory, is not valid. The probable
cause is power was lost. When the unit is off, the bat
-
teries, if charged and present, or power from the AC
mains adapter, if connected, supply power to retain
stored trace data and software settings. This informa
-
tion is lost if all power is removed. Clear the error by
pressing the ESC key. Be sure to read battery charging
and replacement sections if the problem persists.